When you consider purchasing this system, you need to know the following information as it is very important. This system requires a pretreatment setup for it to perform like it was designed to.
The pretreatment setup is not guaranteed to work unless recommended by a sales agent according to the water analysis report from a lab. A water analysis report is very important as it determines the pretreatment setup needed to be installed before the reverse osmosis system. As you can see on the sketch above, the pretreatment consists of a Sand/Glass Filter, Carbon Filter, and Antiscalant Dosing system.
Pretreatment setups can consist of even more items installed before the reverse osmosis system. Below is a list of items that could be required as per the water analysis report.
Once all the equipment has been purchased, you will need a qualified technician to complete the setup. We have our qualified technicians trained by the equipment manufacturers to do the installation running of the setup. Should you require us to install the system for you, the sales agent in charge will send you a quote with the installation fee.
1. High pressure pump: CDL12-12 380V 50Hz 3P Q=9m3,H=130m 5.5KW 3P (Raw water pump EHM10-4;Q=9m3,H=55m 3KW 3P) | |
2. FRP membrane housing 8040*2element*3 300PSI | |
3. RO membrane 8040*6PCS | |
4. SS304 precision filter housing 40"*5 element | |
5. Brass Solenoid valve DN50*1PCS, DN32*1PCS (inlet valve 2''; flush valve 1.2'' ) | |
6. SS304 Globe Valve DN15*1PCS, DN20*1PCS,DN25*1PCS | |
7. Coated electric box*1pcs | |
8. Pressure switch:-0.5~3bar*1pcs,5~30bar*1pcs | |
9. UPVC pipe PN16 *1 lot | |
10. Flow meter: tube type 0.6-6T/H*1pcs, 1-10T/H*1pcs waste water flow meter0.6-6T/H*1pcs, produce water flow meter 1-10T/H*1pcs | |
11. Pressure gage: panel type 2.5MPa*2pcs, tube type:1.0MPa*2pcs, 2.5MPa*1pcs, |
Model | RO6000LPH |
Capacity | 6T/ h - 6000LPH |
Power kW | 7.5 kW |
Inlet pressure | 3 Bars |
Running Pressure | 10-15 Bars |
Voltage | 380v/ 50hz, 3P |
Membrane Recovery rate | 15% |
Desalinization rate | 95% - 98% |
System recovery | 50% |
Max. TDS Input | 2000ppm |
Max. Input Temp. | 30˚C |
Inlet pipe size | 2” |
Product water pipe size | 1.5” |
Waste water pipe size | 1.2” |
System power consumption | 10 kW |
Title |
Default Title |
---|
Your Custom field here