REVERSE OSMOSER MEMBRANE 3013 - 400 GPD

Domestic reverse osmosis membrane with 400 GPD

This reverse osmosis membrane element equips direct-process domestic reverse osmosis equipment to provide consistent performance with long service life. It is compatible with all 3013 membrane holders. 
This membrane is intended to operate in an osmosis system with a direct flow, without a tank.

Notes: Permeate of a single element may vary within [-20%] ~ [+20%]

Dimensions: 1.0 inch = 25.4 mm


TESTING CONDITIONS:

  • Testing Pressure ………………………………… 100 psi (0.41MPa)
  • The temperature of Testing Solution ……………….. 25℃
  • The concentration of Testing Solution (NaCl) ……… 500 ppm
  • the pH of Testing Solution ………………………….. 6.5~8.5
  • Recovery of Single Element……………………. 15%


Performance of the Reverse Osmosis membrane 3013:

  • Maximum production: 400 GPD at 25° C
  • Maximum operating pressure: 300 psi - 2.07 MPa
  • Maximum inlet temperature: 45° C
  • Maximum loss of heat: 10 psi
  • Maximum water turbidity: 1 NTU
  • Maximum dirt density: 5 SDI- Chlorine tolerance: 0.1 ppm maximum
  • Iron, manganese, maximum: 0.1 ppm


Dimensions:

  • Length: 13 inches
  • 3 inches diameter


The membranes should be stored wet and sealed in the original containers.
If the membrane is already wet, it should not dry out. Drying the membrane will cause irreversible changes.
The action of chlorine can damage the membranes.
In case of prolonged stoppage, it is recommended to immerse the membrane in a suitable protection solution to prevent biological growth.
When using or replacing the membrane for the first time, it is necessary to rinse for 0.5 to 1 hour. So keep it - discard the product.

The warranty is void for deposits fouled by deposits or biological growth, misused, poorly maintained, or stored.

TFC Nominal Rejection Characteristics:

  • Calcium: 93-98%
  • Sodium: 92-98%
  • Magnesium: 93-98%
  • Potassium: 92-96%
  • Manganese: 96-98%
  • Iron: 96-98%
  • Aluminum: 96-98%
  • Copper: 96-98%
  • Nickel: 96-98%
  • Cadmium: 93-97%
  • Silver: 93-96%
  • Zinc: 96-98%
  • Mercury: 94-97%
  • Hardness Ca & Mg: 93-97%
  • Radioactivity: 93-97%
  • Chloride: 92-95%
  • Ammonium: 80-90%
  • Bromide: 90-95%
  • Phosphate: 95-98%
  • Chromate: 85-95%
  • Cyanide: 85-95%
  • Sulfate: 96-98%
  • Thiosulfate: 96-98%
  • Silicate: 92-95%
  • Silica: 80-90%
  • Nitrate: 90-95%
  • Boron: 50-70%
  • Borate: 30-50%
  • Fluoride: 92-95%
  • Polyphosphate: 96-98%
  • Orthophosphate: 96-98%
  • Chromate: 85-95%
  • Virus and Bacteria: 99% +
  • Lead: 95-98%


Read more
Read less
👀
people are viewing this right now

SKU:ULP3013-400

Vendor: puritechwater
Size chart
  • Shipping Available
  • 100% money back guarantee
  • T&Cs Apply on Warranty
Payment methods
    View Product details
    product-img
    3013 400 GPD Vontron RO Membrane
    Regular price R 1,104.00 ZAR
    Regular price Sale price R 1,104.00 ZAR
    Tax included.

    REVERSE OSMOSER MEMBRANE 3013 - 400 GPD

    Domestic reverse osmosis membrane with 400 GPD

    This reverse osmosis membrane element equips direct-process domestic reverse osmosis equipment to provide consistent performance with long service life. It is compatible with all 3013 membrane holders. 
    This membrane is intended to operate in an osmosis system with a direct flow, without a tank.

    Notes: Permeate of a single element may vary within [-20%] ~ [+20%]

    Dimensions: 1.0 inch = 25.4 mm


    TESTING CONDITIONS:

    • Testing Pressure ………………………………… 100 psi (0.41MPa)
    • The temperature of Testing Solution ……………….. 25℃
    • The concentration of Testing Solution (NaCl) ……… 500 ppm
    • the pH of Testing Solution ………………………….. 6.5~8.5
    • Recovery of Single Element……………………. 15%


    Performance of the Reverse Osmosis membrane 3013:

    • Maximum production: 400 GPD at 25° C
    • Maximum operating pressure: 300 psi - 2.07 MPa
    • Maximum inlet temperature: 45° C
    • Maximum loss of heat: 10 psi
    • Maximum water turbidity: 1 NTU
    • Maximum dirt density: 5 SDI- Chlorine tolerance: 0.1 ppm maximum
    • Iron, manganese, maximum: 0.1 ppm


    Dimensions:

    • Length: 13 inches
    • 3 inches diameter


    The membranes should be stored wet and sealed in the original containers.
    If the membrane is already wet, it should not dry out. Drying the membrane will cause irreversible changes.
    The action of chlorine can damage the membranes.
    In case of prolonged stoppage, it is recommended to immerse the membrane in a suitable protection solution to prevent biological growth.
    When using or replacing the membrane for the first time, it is necessary to rinse for 0.5 to 1 hour. So keep it - discard the product.

    The warranty is void for deposits fouled by deposits or biological growth, misused, poorly maintained, or stored.

    TFC Nominal Rejection Characteristics:

    • Calcium: 93-98%
    • Sodium: 92-98%
    • Magnesium: 93-98%
    • Potassium: 92-96%
    • Manganese: 96-98%
    • Iron: 96-98%
    • Aluminum: 96-98%
    • Copper: 96-98%
    • Nickel: 96-98%
    • Cadmium: 93-97%
    • Silver: 93-96%
    • Zinc: 96-98%
    • Mercury: 94-97%
    • Hardness Ca & Mg: 93-97%
    • Radioactivity: 93-97%
    • Chloride: 92-95%
    • Ammonium: 80-90%
    • Bromide: 90-95%
    • Phosphate: 95-98%
    • Chromate: 85-95%
    • Cyanide: 85-95%
    • Sulfate: 96-98%
    • Thiosulfate: 96-98%
    • Silicate: 92-95%
    • Silica: 80-90%
    • Nitrate: 90-95%
    • Boron: 50-70%
    • Borate: 30-50%
    • Fluoride: 92-95%
    • Polyphosphate: 96-98%
    • Orthophosphate: 96-98%
    • Chromate: 85-95%
    • Virus and Bacteria: 99% +
    • Lead: 95-98%